PCS2_a118 — Dcdc Failed To Precharge To Target
Full alert identifier: PCS2_a118_dcdcFailedToPrechargeToTarget
Alert description
The Power Conversion System (PCS) cannot precharge the high voltage (HV) bus.
Potential impact
The DCDC converter may not precharge the HV bus to its commanded voltage target, preventing HV battery pack contactors from closing.
Set condition
The PCS detects one or more conditions preventing it from precharging the HV bus to its commanded voltage target
Clear condition
The DCDC converter is commanded to shut down or receives a new request to precharge the HV bus.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Hv Voltage Target
PCS2_
|
V |
Present Hv Bus Voltage
PCS2_
|
V |
Present Lv Bus Voltage
PCS2_
|
V |
| Signal | Unit |
|---|---|
Failed To Reach Fixed Target
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a118.