Skip to content

PCS2_a114 — Hv Bus Estimated Impedance Low

Full alert identifier: PCS2_a114_hvBusEstimatedImpedanceLow

Alert description

The Power Conversion System (PCS) detects the estimated high voltage (HV) bus impedance is lower than the expected threshold.

Potential impact

The DCDC converter may not precharge the HV bus to its commanded voltage target, preventing HV battery pack contactors from closing.

Set condition

The estimated HV bus impedance is lower than the expected threshold.

Clear condition

The DCDC converter is commanded to shut down or receives a new request to precharge the HV bus.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Estimated Hvbus Capacitance PCS2_a114_estimatedHvbusCapacitance uF
Estimated Resistance Linear PCS2_a114_estimatedResistanceLinear ohm
Estimated Resistance Logarithm PCS2_a114_estimatedResistanceLogarithm ohm
Signal Unit
Use Linear Result PCS2_a114_useLinearResult —
Use Logarithm Result PCS2_a114_useLogarithmResult —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a114.