Skip to content

PCS2_a105 — Line To Line Rms UV

Full alert identifier: PCS2_a105_LineToLineRmsUV

Alert description

The root mean squared (RMS) voltage from Line to Line has decreased below the expected RMS voltage threshold

Potential impact

AC Charging may be limited or unavailable.

Set condition

The root mean squared (RMS) voltage from Line to Line has decreased below the expected RMS voltage threshold

Clear condition

The root mean squared (RMS) voltage from Line to Line has no longer decreased below the expected RMS voltage threshold

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Line To Line Voltage Rms PCS2_a105_lineToLineVoltageRms V
Under Voltage Rms Threshold PCS2_a105_underVoltageRmsThreshold V
Signal Unit
Itic Curve Section PCS2_a105_iticCurveSection
0
ITIC CURVE SECTION STEADY STATE UV
1
ITIC CURVE SECTION LINE VOLTAGE SAG LEVEL 1 UV
2
ITIC CURVE SECTION LINE VOLTAGE SAG LEVEL 2 UV
3
NUM ITIC CURVE UV SECTIONS
—
Lines Faulted PCS2_a105_linesFaulted
0
L1LN
1
L2LN
2
L3LN
3
L1L2
4
L1L3
5
L2L3
6
NUM AC LINE TO LINE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a105.

Browse all PCS2 alert codes