EPASTS_a129 — Exch Additional Exception Stop Restart

Full alert identifier: EPASTS_a129_exchAdditionalExceptionStopRestart

Alert description

This alert is reported by the ExceptionHandler_TC3x (EXCH) component when no-reset exception occured before the previous similar exception was reported

Potential impact

EPAS still can provide assist. MCU reset on the exception side.

Set condition

EPAS application component ExceptionHandler detected additional exceptions at stop/restart of partition.

Clear condition

Perform EPAS Software update. Replace HW if the alert persists.

Signals to check

These diagnostic fields are associated with EPASTS_a129. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a129_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a129.