Skip to content
Model Y

EPASTS_a127 — Exch Additional Exception After Rst

Full alert identifier: EPASTS_a127_exchAdditionalExceptionAfterRst

Alert description

This alert is reported by the ExceptionHandler_TC3x (EXCH) component when exception with reset before the previous similar error was reported. The alert is reported after reset if several exceptions in ASIL D partition were caught before reset.

Potential impact

EPAS reset

Set condition

EPAS application component ExceptionHandler detected additional exceptions in ASIL D partition after a reset.

Clear condition

Perform EPAS Software update. Replace HW if the alert persists.

Signals to check

These diagnostic fields are associated with EPASTS_a127. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a127_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a127.

Browse all EPASTS alert codes