Skip to content
Model Y

EPASTS_a112 — Rsth Safety Flipflop Err

Full alert identifier: EPASTS_a112_rsthSafetyFlipflopErr

Alert description

This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is a failure to correct data error in critical MCU registers.

Potential impact

EPAS reset

Set condition

EPAS Failure to correct data error in critical MCU registers.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a112. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a112_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a112.

Browse all EPASTS alert codes