Alert description

This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is a Lockstep failure: cores no longer synchronized or provided different values.

Potential impact

EPAS reset

Set condition

EPAS uC dual core lockstep fault (cores no longer sync).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a068. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a068_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a068.