Alert description

This alert is reported by the FdrActiveDetectionPrevention_R12 (FDP) component if there is a problem with the active prevention torque of the freezing detection feature.

Potential impact

Active prevention torque of the freezing detection is inhibited.

Set condition

EPAS freezing active detection prevention torque checker indicates error (prevention torque is switched to zero).

Clear condition

EPAS power cycle.

Signals to check

These diagnostic fields are associated with EPASTP_a204. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a204_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a204.