Skip to content
Model Y

EPASTP_a098 — Inv Err

Full alert identifier: EPASTP_a098_invErr

Alert description

This alert is reported by the InverterDiagnostics_R12 (INV) component if the reconstructed Alpha or Beta vectors are different from the actual Alpha or Beta vectors. This diagnostic compares the input and output of the inverter component. The SwitchOnOffTimes output of the inverter is transformed back into alfa, beta vectors, and checked against the input.

Potential impact

EPAS reset. If reset more than 5 times then EPAS full loss of assist.

Set condition

Reconstructed Alpha or Beta vectors are different from the actual Alpha or Beta vectors. EPAS application diagnostics of inverter device detected failure (in/out-feedback comparison).

Clear condition

EPAS will perform a safety reset.

Signals to check

These diagnostic fields are associated with EPASTP_a098. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a098_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a098.

Browse all EPASTP alert codes