Skip to content
Model Y

EPASTP_a143 — Ted Emifilter Cmc Temp Checker

Full alert identifier: EPASTP_a143_tedEmifilterCmcTempChecker

Alert description

This alert is reported if (DC Link capacitor temperature higher than limit or not available) for at least debounce limit long time. The error is cleared, if the temperature is below the overtemp threshold, and its qualifier is RELIABLE for long enough.

Potential impact

EPAS full loss of assist.

Set condition

EPAS application diagnostics detected overtemperature (CMC EMI filter).

Clear condition

If the temperature is below the overtemp threshold, and its qualifier is RELIABLE

Signals to check

These diagnostic fields are associated with EPASTP_a143. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a143_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a143.

Browse all EPASTP alert codes