Skip to content
Model Y

EPASTP_a083 — Tda Dclinkcapacitor Temp Checker

Full alert identifier: EPASTP_a083_tdaDclinkcapacitorTempChecker

Alert description

This alert is reported by the TemperatureDiagnostics_R12 component when there is a DC-link capacitor overtemperature. Degradation parameters/estimator shall be checked, if those are correct, HW failure.

Potential impact

EPAS full loss of assist.

Set condition

EPAS application actuator temperature diagnostics detected overtemperature (capacitor).

Clear condition

If the temperature is below the overtemp threshold, and its qualifier is RELIABLE for long enough.

Signals to check

These diagnostic fields are associated with EPASTP_a083. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a083_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a083.

Browse all EPASTP alert codes