Skip to content
Model Y

EPASTP_a117 — Mrcc Startup Reg Cs Error Transient Err

Full alert identifier: EPASTP_a117_mrccStartupRegCsErrorTransientErr

Alert description

This alert is reported when there is a transient CRC failure in register CRC check.

Potential impact

EPAS reset. If reset more than 6 then EPAS fallback to bootloader.

Set condition

EPAS microcontroller's different registers does not contain the right values before starting the safety functions (CRC doesn't match for the first test fail).

Clear condition

Perform EPAS Software update. Replace HW if the alert persists.

Signals to check

These diagnostic fields are associated with EPASTP_a117. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a117_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a117.

Browse all EPASTP alert codes