EPASTP_a118 — Mcussc Flash Cs Error Err
Full alert identifier: EPASTP_a118_mcusscFlashCsErrorErr
Alert description
This alert is reported by MCUSafetyStartupChecks_TC3x (MCUSSC) component when the flashed SW is incorrect or flash memory failure. Calculated CRC not matching stored CRC.
Potential impact
EPAS reset. If reset more than 6 then EPAS fallback to bootloader.
Set condition
EPAS has detected flashed SW data integrity failure (CRC).
Clear condition
Perform EPAS Software update.
Signals to check
These diagnostic fields are associated with EPASTP_a118. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a118.