EPASTP_a001 — Adc Calibration Or Init Fail
Full alert identifier: EPASTP_a001_adcCalibrationOrInitFail
Alert description
This alert is reported by the ADCDriverCD_TC3x component when Analog-Digital Converter (ADC) calibration cannot be started, timeout reached. MCU failure.
Potential impact
EPAS full loss of assist. EPAS ADC is considered inoperable.
Set condition
EPAS uC peripheral ADC self calibration timeout at startup.
Clear condition
Perform EPAS ECU power cycle.
Signals to check
These diagnostic fields are associated with EPASTP_a001. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a001.