Skip to content

VCSUPER_a196 — Pt Pump Stopped

Full alert identifier: VCSUPER_a196_ptPumpStopped

Alert description

The vehicle controller detects the powertrain pump motor is experiencing a condition that is preventing the motor from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

For at least 10.5 seconds, the powertrain pump motor's RPM feedback is less than 800 RPM, or the powertrain pump motor is intermittently or continually given a non-zero flow request.

Clear condition

The feedback RPM for the powertrain pump motor is consistently greater than 800 RPM for at least 5.5 seconds.

Signals to check

These diagnostic fields are associated with VCSUPER_a196. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
RPM Actual VCSUPER_a196_RPMActual RPM
RPM Target VCSUPER_a196_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSUPER_a196.

Browse all VCSUPER alert codes