Skip to content

VCSUPER_a192 — Pt Pump General Fault

Full alert identifier: VCSUPER_a192_ptPumpGeneralFault

Alert description

The powertrain pump brushless motor experienced a general condition affecting its operation.

Potential impact

The powertrain pump does not operate. Vehicle functions relying on the powertrain pump may not operate as expected.

Set condition

The powertrain pump motor controller reports a condition affecting its operation.

Clear condition

The powertrain pump motor controller does not report a condition affecting its operation.

Signals to check

These diagnostic fields are associated with VCSUPER_a192. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Voltage Irrational VCSUPER_a192_busVoltageIrrational —
Bus Voltage Unhealthy VCSUPER_a192_busVoltageUnhealthy —
Chip Overtemp VCSUPER_a192_chipOvertemp —
Dc Current Irrational VCSUPER_a192_dcCurrentIrrational —
Dc Overcurrent VCSUPER_a192_dcOvercurrent —
Ecu Reset VCSUPER_a192_ecuReset —
Fet Temp Irrational VCSUPER_a192_fetTempIrrational —
Hardware Overcurrent VCSUPER_a192_hardwareOvercurrent —
Show 25 more fields
Signal Unit
Hs Vds Overvoltage VCSUPER_a192_hsVdsOvervoltage —
Hs Vds Overvoltage Mask VCSUPER_a192_hsVdsOvervoltageMask —
Lin Checksum Error VCSUPER_a192_linChecksumError —
Lin Framing Error VCSUPER_a192_linFramingError —
Ls Vds Overvoltage VCSUPER_a192_lsVdsOvervoltage —
Ls Vds Overvoltage Mask VCSUPER_a192_lsVdsOvervoltageMask —
Motor Control Error VCSUPER_a192_motorControlError —
Motor Faulted VCSUPER_a192_motorFaulted —
Motor Locked VCSUPER_a192_motorLocked —
Motor Open Phase VCSUPER_a192_motorOpenPhase —
Motor Overtemp VCSUPER_a192_motorOvertemp —
Motor Phase Current Irrational VCSUPER_a192_motorPhaseCurrentIrrational —
Motor Soft Open Phase VCSUPER_a192_motorSoftOpenPhase —
Motor Speed Irrational VCSUPER_a192_motorSpeedIrrational —
Motor Speed Too High VCSUPER_a192_motorSpeedTooHigh —
Motor Stalled VCSUPER_a192_motorStalled —
Over Voltage VCSUPER_a192_overVoltage —
Payload Bits Not Set VCSUPER_a192_payloadBitsNotSet —
Phase Overcurrent VCSUPER_a192_phaseOvercurrent —
Phase Shorted VCSUPER_a192_phaseShorted —
Self Test Failed VCSUPER_a192_selfTestFailed —
Self Test Result VCSUPER_a192_selfTestResult
0
NOT TESTED
1
SHORT SUPPLY
2
SHORT GROUND
3
OPEN PHASE U
4
OPEN PHASE V
5
OPEN PHASE W
6
UNKNOWN
7
PASSED
—
Supply Voltage Irrational VCSUPER_a192_supplyVoltageIrrational —
Under Voltage VCSUPER_a192_underVoltage —
Vdda Overcurrent VCSUPER_a192_vddaOvercurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSUPER_a192.

Browse all VCSUPER alert codes