VCSUPER_a192 — Pt Pump General Fault
Full alert identifier: VCSUPER_a192_ptPumpGeneralFault
Alert description
The powertrain pump brushless motor experienced a general condition affecting its operation.
Potential impact
The powertrain pump does not operate. Vehicle functions relying on the powertrain pump may not operate as expected.
Set condition
The powertrain pump motor controller reports a condition affecting its operation.
Clear condition
The powertrain pump motor controller does not report a condition affecting its operation.
Signals to check
These diagnostic fields are associated with VCSUPER_a192. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bus Voltage Irrational
VCSUPER_
|
— |
Bus Voltage Unhealthy
VCSUPER_
|
— |
Chip Overtemp
VCSUPER_
|
— |
Dc Current Irrational
VCSUPER_
|
— |
Dc Overcurrent
VCSUPER_
|
— |
Ecu Reset
VCSUPER_
|
— |
Fet Temp Irrational
VCSUPER_
|
— |
Hardware Overcurrent
VCSUPER_
|
— |
Show 25 more fields
| Signal | Unit |
|---|---|
Hs Vds Overvoltage
VCSUPER_
|
— |
Hs Vds Overvoltage Mask
VCSUPER_
|
— |
Lin Checksum Error
VCSUPER_
|
— |
Lin Framing Error
VCSUPER_
|
— |
Ls Vds Overvoltage
VCSUPER_
|
— |
Ls Vds Overvoltage Mask
VCSUPER_
|
— |
Motor Control Error
VCSUPER_
|
— |
Motor Faulted
VCSUPER_
|
— |
Motor Locked
VCSUPER_
|
— |
Motor Open Phase
VCSUPER_
|
— |
Motor Overtemp
VCSUPER_
|
— |
Motor Phase Current Irrational
VCSUPER_
|
— |
Motor Soft Open Phase
VCSUPER_
|
— |
Motor Speed Irrational
VCSUPER_
|
— |
Motor Speed Too High
VCSUPER_
|
— |
Motor Stalled
VCSUPER_
|
— |
Over Voltage
VCSUPER_
|
— |
Payload Bits Not Set
VCSUPER_
|
— |
Phase Overcurrent
VCSUPER_
|
— |
Phase Shorted
VCSUPER_
|
— |
Self Test Failed
VCSUPER_
|
— |
Self Test Result
VCSUPER_
|
— |
Supply Voltage Irrational
VCSUPER_
|
— |
Under Voltage
VCSUPER_
|
— |
Vdda Overcurrent
VCSUPER_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCSUPER_a192.