VCRIGHT_a538 — Hvac System Not Nominal
Full alert identifier: VCRIGHT_a538_hvacSystemNotNominal
Alert description
The right vehicle controller (VCRIGHT) detects the HVAC system is not nominal due to a condition, which may cause Climate Keeper Mode functionality to be limited or unavailable.
Potential impact
Climate Keeper Mode functionality may be limited or unavailable.
Set condition
The VCRIGHT detects the HVAC system is not nominal for 30 seconds due to a condition. Alert log signal data should provide more information on the specific condition(s) detected.
Clear condition
The VCRIGHT does not detect a condition on the HVAC system for 10 seconds, allowing the HVAC system to be nominal.
Signals to check
These diagnostic fields are associated with VCRIGHT_a538. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Airpaths Blocked
VCRIGHT_
|
— |
Blower Fault Or Stopped
VCRIGHT_
|
— |
Cabin Model Not Initialized
VCRIGHT_
|
— |
Cabin Temp Sensor Fault
VCRIGHT_
|
— |
Compressor Fault Or Standby
VCRIGHT_
|
— |
Duct Temp Sensor Fault
VCRIGHT_
|
— |
Evap Temp Sensor Fault
VCRIGHT_
|
— |
Heat Pump Mode Not Attainable
VCRIGHT_
|
— |
Show 6 more fields
| Signal | Unit |
|---|---|
Hv On
VCRIGHT_
|
— |
Hvac Power On
VCRIGHT_
|
— |
Limp Mode
VCRIGHT_
|
— |
Ptc Heater Fault
VCRIGHT_
|
— |
Ths Mia
VCRIGHT_
|
— |
Ths Version Mismatch
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a538.