Skip to content

VCRIGHT_a124 — HVBATTCON MIA

Full alert identifier: VCRIGHT_a124_HVBATTCON_MIA

Alert description

One or more of the messages the vehicle controller receives periodically from the High Voltage Battery Management System Controller (HVBATTCON) is not received, indicating the HVBATTCON may be unavailable (MIA).

Potential impact

Vehicle functions that depend on the HVBATTCON may be unavailable or may not function as expected.

Set condition

The vehicle controller does not receive one or more of the expected messages from the HVBATTCON within the expected time frame.

Clear condition

The vehicle controller receives the expected messages from the HVBATTCON.

Signals to check

These diagnostic fields are associated with VCRIGHT_a124. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
LOOP Charge Info VCRIGHT_a124_LOOP_chargeInfo —
LOOP Energy Status VCRIGHT_a124_LOOP_energyStatus —
LOOP Grid Form Info VCRIGHT_a124_LOOP_gridFormInfo —
THERMAL Charge Info VCRIGHT_a124_THERMAL_chargeInfo —
THERMAL Charge Status VCRIGHT_a124_THERMAL_chargeStatus —
THERMAL Soc Status VCRIGHT_a124_THERMAL_socStatus —
THERMAL Status VCRIGHT_a124_THERMAL_status —
THERMAL Thermal Status VCRIGHT_a124_THERMAL_thermalStatus —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a124.

Browse all VCRIGHT alert codes