VCRIGHT_a499 — Vnf1048 Wake Failure

Full alert identifier: VCRIGHT_a499_vnf1048WakeFailure

Alert description

The VNF1048 eFuse does not wake as expected. Vehicle functions controlled by the impacted VNF1048 may not operate as expected.

Potential impact

Loads powered by an VNF1048 with this condition may not function or may experience a delay when first using the vehicle.

Set condition

A VNF1048 eFuse is determined to have not woken up properly

Clear condition

VNF1048 eFuse wakes up nominally.

Signals to check

These diagnostic fields are associated with VCRIGHT_a499. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Channel VCRIGHT_a499_channel —
State VCRIGHT_a499_state
0
UNKNOWN
1
STANDBY
2
WAKEUP
3
CONFIGURATION
4
UNLOCKED
5
LOCKED
6
SELF TEST PREP
7
SELF TEST
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a499.