VCRIGHT_a414 — Undervoltage Self Test Failure

Full alert identifier: VCRIGHT_a414_undervoltageSelfTestFailure

Alert description

The Right Domain Undervoltage self-test did not pass, as a condition affecting a load on the Right Domain was detected during the self-test.

Potential impact

The undervoltage protection circuit may not be functional.

Set condition

The Right Domain Undervoltage self-test does not succeed. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.

Clear condition

Vehicle controller reset or successful Right Domain Undervoltage self-test.

Signals to check

These diagnostic fields are associated with VCRIGHT_a414. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bridge Shutdown Active VCRIGHT_a414_bridgeShutdownActive —
Device Stuck On Failure VCRIGHT_a414_deviceStuckOnFailure —
Failure Reason VCRIGHT_a414_failureReason
0
NONE
1
DEVICE STUCK ON
2
BRIDGE
3
BRIDGE AND DEVICE STUCK ON
4
LOAD UNATTEMPTED ON
8
FOLLOWER
16
TIMEOUT
—
Follower Egg Right 1 Self Test Failure VCRIGHT_a414_followerEggRight1SelfTestFailure —
Follower Vcrear Self Test Failure VCRIGHT_a414_followerVcrearSelfTestFailure —
Load Unattempted On Failure VCRIGHT_a414_loadUnattemptedOnFailure —
Uv Loadshed Vsense Dig In VCRIGHT_a414_uvLoadshedVsenseDigIn —