VCRIGHT_a205 — Overvoltage Shutdown Triggered
Full alert identifier: VCRIGHT_a205_overvoltageShutdownTriggered
Alert description
Overvoltage protection has tripped on the Right Vehicle Controller (VCRIGHT). Low Voltage (LV) bridge is expected to be open until the protection is cleared.
Potential impact
LV bridge is open.
Set condition
48V bus is reported overvoltage on VCRIGHT while the vehicle is in Drive.
Clear condition
Overvoltage protection resets when the vehicle is parked and the 48V bus voltage falls below 56V.
Signals to check
These diagnostic fields are associated with VCRIGHT_a205. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Rail Voltage
VCRIGHT_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a205.