VCRIGHT_a194 — Blower General Fault
Full alert identifier: VCRIGHT_a194_blowerGeneralFault
Alert description
The brushless motor has a general fault
Potential impact
The HVAC blower will not be able to run. The integrated circuit will clear the fault when the condition is no longer present
Set condition
The MLX motor controller detected an error
Clear condition
The MLX motor controller no longer detects an error
Signals to check
These diagnostic fields are associated with VCRIGHT_a194. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bus Voltage Irrational
VCRIGHT_
|
— |
Bus Voltage Unhealthy
VCRIGHT_
|
— |
Chip Overtemp
VCRIGHT_
|
— |
Dc Current Irrational
VCRIGHT_
|
— |
Dc Overcurrent
VCRIGHT_
|
— |
Ecu Reset
VCRIGHT_
|
— |
Fet Temp Irrational
VCRIGHT_
|
— |
Hardware Overcurrent
VCRIGHT_
|
— |
Show 25 more fields
| Signal | Unit |
|---|---|
Hs Vds Overvoltage
VCRIGHT_
|
— |
Hs Vds Overvoltage Mask
VCRIGHT_
|
— |
Lin Checksum Error
VCRIGHT_
|
— |
Lin Framing Error
VCRIGHT_
|
— |
Ls Vds Overvoltage
VCRIGHT_
|
— |
Ls Vds Overvoltage Mask
VCRIGHT_
|
— |
Motor Control Error
VCRIGHT_
|
— |
Motor Faulted
VCRIGHT_
|
— |
Motor Locked
VCRIGHT_
|
— |
Motor Open Phase
VCRIGHT_
|
— |
Motor Overtemp
VCRIGHT_
|
— |
Motor Phase Current Irrational
VCRIGHT_
|
— |
Motor Soft Open Phase
VCRIGHT_
|
— |
Motor Speed Irrational
VCRIGHT_
|
— |
Motor Speed Too High
VCRIGHT_
|
— |
Motor Stalled
VCRIGHT_
|
— |
Over Voltage
VCRIGHT_
|
— |
Payload Bits Not Set
VCRIGHT_
|
— |
Phase Overcurrent
VCRIGHT_
|
— |
Phase Shorted
VCRIGHT_
|
— |
Self Test Failed
VCRIGHT_
|
— |
Self Test Result
VCRIGHT_
|
— |
Supply Voltage Irrational
VCRIGHT_
|
— |
Under Voltage
VCRIGHT_
|
— |
Vdda Overcurrent
VCRIGHT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a194.