Skip to content

VCRIGHT_a192 — Rad Fan General Fault

Full alert identifier: VCRIGHT_a192_radFanGeneralFault

Alert description

The radiator fan brushless motor controller reports a condition affecting its operation.

Potential impact

The radiator fan will not be able to run.

Set condition

The radiator fan motor controller reports a condition affecting the radiator fan operation.

Clear condition

The radiator fan motor controller no longer reports an issue affecting the radiator fan operation.

Signals to check

These diagnostic fields are associated with VCRIGHT_a192. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Voltage Irrational VCRIGHT_a192_busVoltageIrrational —
Bus Voltage Unhealthy VCRIGHT_a192_busVoltageUnhealthy —
Chip Overtemp VCRIGHT_a192_chipOvertemp —
Dc Current Irrational VCRIGHT_a192_dcCurrentIrrational —
Dc Overcurrent VCRIGHT_a192_dcOvercurrent —
Ecu Reset VCRIGHT_a192_ecuReset —
Fet Temp Irrational VCRIGHT_a192_fetTempIrrational —
Hardware Overcurrent VCRIGHT_a192_hardwareOvercurrent —
Show 25 more fields
Signal Unit
Hs Vds Overvoltage VCRIGHT_a192_hsVdsOvervoltage —
Hs Vds Overvoltage Mask VCRIGHT_a192_hsVdsOvervoltageMask —
Lin Checksum Error VCRIGHT_a192_linChecksumError —
Lin Framing Error VCRIGHT_a192_linFramingError —
Ls Vds Overvoltage VCRIGHT_a192_lsVdsOvervoltage —
Ls Vds Overvoltage Mask VCRIGHT_a192_lsVdsOvervoltageMask —
Motor Control Error VCRIGHT_a192_motorControlError —
Motor Faulted VCRIGHT_a192_motorFaulted —
Motor Locked VCRIGHT_a192_motorLocked —
Motor Open Phase VCRIGHT_a192_motorOpenPhase —
Motor Overtemp VCRIGHT_a192_motorOvertemp —
Motor Phase Current Irrational VCRIGHT_a192_motorPhaseCurrentIrrational —
Motor Soft Open Phase VCRIGHT_a192_motorSoftOpenPhase —
Motor Speed Irrational VCRIGHT_a192_motorSpeedIrrational —
Motor Speed Too High VCRIGHT_a192_motorSpeedTooHigh —
Motor Stalled VCRIGHT_a192_motorStalled —
Over Voltage VCRIGHT_a192_overVoltage —
Payload Bits Not Set VCRIGHT_a192_payloadBitsNotSet —
Phase Overcurrent VCRIGHT_a192_phaseOvercurrent —
Phase Shorted VCRIGHT_a192_phaseShorted —
Self Test Failed VCRIGHT_a192_selfTestFailed —
Self Test Result VCRIGHT_a192_selfTestResult
0
NOT TESTED
1
SHORT SUPPLY
2
SHORT GROUND
3
OPEN PHASE U
4
OPEN PHASE V
5
OPEN PHASE W
6
UNKNOWN
7
PASSED
—
Supply Voltage Irrational VCRIGHT_a192_supplyVoltageIrrational —
Under Voltage VCRIGHT_a192_underVoltage —
Vdda Overcurrent VCRIGHT_a192_vddaOvercurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a192.

Browse all VCRIGHT alert codes