VCREAR_a511 — DCDC Saturation Load Shed

Full alert identifier: VCREAR_a511_DCDCSaturationLoadShed

Alert description

Electrical current flowing through the power conversion system (PCS) eFuse is approaching the DCDC converter's maximum handling capacity. The left vehicle controller (VCLEFT) is shedding some vehicle electrical loads by cutting power to less essential electronic control units (ECUs).

Potential impact

Some convenience features will be unavailable as VCLEFT limits LV electrical system current draw by cutting power to some electronic control units (ECUs).

Set condition

The DCDC reports it is saturated for 2 seconds.

Clear condition

The DCDC reports it is no longer saturated for long enough for VCLEFT to stop loadshedding (until DCDC Saturation Loadshed Stage is MIN).

Signals to check

These diagnostic fields are associated with VCREAR_a511. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
DCDC Continuous Power Limit VCREAR_a511_DCDCContinuousPowerLimit W
DCDC Output Limited VCREAR_a511_DCDCOutputLimited —
DCDC Output Power VCREAR_a511_DCDCOutputPower W
DCDC Support Status VCREAR_a511_DCDCSupportStatus
0
IDLE
1
ACTIVE
2
FAULTED
—
PCS Signals Are Valid VCREAR_a511_PCSSignalsAreValid —
Factory Gated VCREAR_a511_factoryGated —
Jump Post Active VCREAR_a511_jumpPostActive —
Service Mode VCREAR_a511_serviceMode —
Show 1 more field
Signal Unit
Vehicle Is Updating VCREAR_a511_vehicleIsUpdating —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a511.