Skip to content

VCREAR_a415 — Undervoltage Self Test Stuck Off

Full alert identifier: VCREAR_a415_undervoltageSelfTestStuckOff

Alert description

One or more loads failed to turn on during the Right Domain Undervoltage Self-Test. Those loads will be inhibited from use in drive.

Potential impact

Impacted load(s) will not be usable in drive.

Set condition

One or more loads failed to turn on during the Right Domain Undervoltage Self-Test.

Clear condition

The Right Domain Undervoltage self-test is ran again and the load is turned on successfully.

Signals to check

These diagnostic fields are associated with VCREAR_a415. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Audio Amplifier Stuck Off VCREAR_a415_audioAmplifierStuckOff —
Cross Car Bar Light Stuck Off VCREAR_a415_crossCarBarLightStuckOff —
Diff Or Trimotor Oil Pump Stuck Off VCREAR_a415_diffOrTrimotorOilPumpStuckOff —
Rear Left Seat Heater Stuck Off VCREAR_a415_rearLeftSeatHeaterStuckOff —
Rear Oil Pump Stuck Off VCREAR_a415_rearOilPumpStuckOff —
Rear Right Seat Heater Stuck Off VCREAR_a415_rearRightSeatHeaterStuckOff —
Rear Steer Stuck Off VCREAR_a415_rearSteerStuckOff —
Vbus 15 V Fused Stuck Off VCREAR_a415_vbus15VFusedStuckOff —
Show 1 more field
Signal Unit
Vbus 48 V Fused Stuck Off VCREAR_a415_vbus48VFusedStuckOff —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a415.

Browse all VCREAR alert codes