Skip to content

VCREAR_a206 — Pcs Ov Shutdown Self Test Failure

Full alert identifier: VCREAR_a206_pcsOvShutdownSelfTestFailure

Alert description

Power Conversion System (PCS) Overvoltage Shutdown protection has become active on the Rear Vehicle Controller (VCREAR).

Potential impact

PCS is unavailable due to overvoltage shutdown protection becoming active. Separate LVUnhealthy alert indicating a condition affecting low voltage (LV) electrical system will also be present.

Set condition

Overvoltage condition on 48V bus detected by VCREAR while the vehicle is in drive.

Clear condition

PCS Overvoltage Shutdown protection will be reset once the vehicle is parked and the 48V bus voltage is below 56V.

Signals to check

These diagnostic fields are associated with VCREAR_a206. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ov Critical Shutdown Armed VCREAR_a206_ovCriticalShutdownArmed —
Ov Critical Shutdown Dig In VCREAR_a206_ovCriticalShutdownDigIn —
Pcs Enable Feedback VCREAR_a206_pcsEnableFeedback —
Pcs Enable Line Voltage VCREAR_a206_pcsEnableLineVoltage V
Pcs Supporting VCREAR_a206_pcsSupporting —
Pcs Supporting Valid VCREAR_a206_pcsSupportingValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a206.

Browse all VCREAR alert codes