VCREAR_a204 — Undervoltage Loadshed Triggered
Full alert identifier: VCREAR_a204_undervoltageLoadshedTriggered
Alert description
Undervoltage loadshed protection has tripped on the Rear Vehicle Controller (VCREAR). Low Voltage (LV) bridge is expected to be open until the protection is cleared.
Potential impact
LV bridge is open. Impacted load(s) unavailable in Drive.
Set condition
48V bus is reported undervoltage on VCREAR while the vehicle is in Drive.
Clear condition
Undervoltage loadshed protection resets when the vehicle is parked and the 48V bus voltage exceeds 28V.
Signals to check
These diagnostic fields are associated with VCREAR_a204. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Vbus Voltage
VCREAR_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a204.