VCLEFT_a402 — LV Battery Cannot Support Vehicle

Full alert identifier: VCLEFT_a402_LVBatteryCannotSupportVehicle

Alert description

The vehicle controller has detected a condition where the low voltage (LV) battery is unable to support vehicle electrical systems. The vehicle is likely to shut down if high voltage (HV) battery support for vehicle electrical systems via the power conversion system (PCS) is lost, so the HV system will remain energized to continue supplying electrical power to the vehicle until the alert clears.

Potential impact

The LV battery is unable to support vehicle electrical systems. The high voltage (HV) system will remain energized to continue supplying electrical power to the vehicle while the LV battery is unavailable. This may result in greater range loss than expected, increased HV system energy consumption when the vehicle is idle, and prevent the vehicle from sleeping.

Set condition

The LV battery is disconnected or showing degraded functionality, the LV battery internal protection transistor (MOSFET) is detected open, or the reverse battery eFuse has tripped (circuit is open).

Clear condition

The vehicle controller no longer detects a condition where the LV battery is unable to support vehicle electrical systems. May include reconnecting or replacing the LV battery, the LV battery internal protection transistor (MOSFET) being detected closed, or reverse battery eFuse no longer tripped (circuit closed again).

Signals to check

These diagnostic fields are associated with VCLEFT_a402. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
LV Battery Temp VCLEFT_a402_LVBatteryTemp
127
SNA
degC
MOS Open VCLEFT_a402_MOSOpen —
Battery SM State VCLEFT_a402_batterySMState
0
INIT
1
CHARGE
2
DISCHARGE
3
STANDBY
8
FAULT
—
Communication Disconnect LV Battery VCLEFT_a402_communicationDisconnectLVBattery —
Electrical Disconnect LV Battery VCLEFT_a402_electricalDisconnectLVBattery —
Failure To Precharge Risk VCLEFT_a402_failureToPrechargeRisk —
Frunk Open VCLEFT_a402_frunkOpen —
Reverse Battery Fault VCLEFT_a402_reverseBatteryFault —
Show 1 more field
Signal Unit
Service Mode VCLEFT_a402_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a402.

Browse all VCLEFT alert codes