VCLEFT_a397 — Frunk Latch Rehome Left Home
Full alert identifier: VCLEFT_a397_frunkLatchRehomeLeftHome
Alert description
The frunk latch home switch transitioned to inactive during a homing actuation.
Potential impact
The frunk latch switches or actuator may not be functioning correctly, leading to degraded latch functionality.
Set condition
The frunk latch home switch transitioned to active after beginning a homing actuation.
Clear condition
A new frunk latch actuation (cinch or release) is started.
Signals to check
These diagnostic fields are associated with VCLEFT_a397. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp
VCLEFT_
|
degC |
Frunk Latch State
VCLEFT_
|
— |
Frunk Latch State Prev
VCLEFT_
|
— |
Lift 1 Switch Status
VCLEFT_
|
— |
Lift 2 Switch Status
VCLEFT_
|
— |
Pawl Full Open Switch Active
VCLEFT_
|
— |
Pawl Switch Active
VCLEFT_
|
— |
Vbus 16 VSW
VCLEFT_
|
V |
Show 2 more fields
| Signal | Unit |
|---|---|
Vbus 3 V 3 SW
VCLEFT_
|
V |
Vbus 3 V 3 SW Stable
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a397.