Skip to content

VCLEFT_a396 — Frunk Latch Rehome Timed Out

Full alert identifier: VCLEFT_a396_frunkLatchRehomeTimedOut

Alert description

The frunk latch home switch did not transition to active after a homing actuation timed out.

Potential impact

The frunk latch switches or actuator may not be functioning correctly, leading to degraded latch functionality.

Set condition

The frunk latch home switch did not transition to active after a homing actuation time-out reached.

Clear condition

A new frunk latch actuation (cinch or release) is started.

Signals to check

These diagnostic fields are associated with VCLEFT_a396. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp VCLEFT_a396_ambientTemp degC
Frunk Latch State VCLEFT_a396_frunkLatchState —
Frunk Latch State Prev VCLEFT_a396_frunkLatchStatePrev —
Lift 1 Switch Status VCLEFT_a396_lift1SwitchStatus
0
SNA
1
OFF
2
ON
3
FAULT
—
Lift 2 Switch Status VCLEFT_a396_lift2SwitchStatus
0
SNA
1
OFF
2
ON
3
FAULT
—
Pawl Full Open Switch Active VCLEFT_a396_pawlFullOpenSwitchActive —
Pawl Switch Active VCLEFT_a396_pawlSwitchActive —
Vbus 16 VSW VCLEFT_a396_vbus16VSW V
Show 2 more fields
Signal Unit
Vbus 3 V 3 SW VCLEFT_a396_vbus3V3SW V
Vbus 3 V 3 SW Stable VCLEFT_a396_vbus3V3SWStable —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a396.

Browse all VCLEFT alert codes