VCLEFT_a395 — Frunk Latch Unexpected Switch States
Full alert identifier: VCLEFT_a395_frunkLatchUnexpectedSwitchStates
Alert description
The frunk latch switches did not match their expected status upon exiting frunkLatchStatePrev. Latch may be damaged or degraded.
Potential impact
The frunk latch, switches, or actuator may be damaged or not functioning correctly, leading to degraded latch functionality.
Set condition
The frunk latch lift and/or pawl switches did not match their expected status upon exiting frunkLatchStatePrev.
Clear condition
A new frunk latch actuation is started that causes a transition through the identified frunkLatchStatePrev state, and upon exiting this state the switches match their expected status.
Signals to check
These diagnostic fields are associated with VCLEFT_a395. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temp
VCLEFT_
|
degC |
Error After Cinch
VCLEFT_
|
— |
Error After Homing Closed
VCLEFT_
|
— |
Error After Homing Opened
VCLEFT_
|
— |
Error After Releasing Primary Extending
VCLEFT_
|
— |
Error After Releasing Retracting
VCLEFT_
|
— |
Error After Releasing Secondary Delay
VCLEFT_
|
— |
Frunk Latch State
VCLEFT_
|
— |
Show 8 more fields
| Signal | Unit |
|---|---|
Frunk Latch State Prev
VCLEFT_
|
— |
Lift 1 Switch Status
VCLEFT_
|
— |
Lift 2 Switch Status
VCLEFT_
|
— |
Pawl Full Open Switch Active
VCLEFT_
|
— |
Pawl Switch Active
VCLEFT_
|
— |
Vbus 16 VSW
VCLEFT_
|
V |
Vbus 3 V 3 SW
VCLEFT_
|
V |
Vbus 3 V 3 SW Stable
VCLEFT_
|
— |
Check other alerts