Skip to content

VCLEFT_a350 — Ens Out Of Range

Full alert identifier: VCLEFT_a350_ensOutOfRange

Alert description

The Emergency Notification Signal (ENS) harness may be disconnected or the Restraints Control Module (RCM) may be missing (MIA).

Potential impact

Loss of redundancy on high voltage disconnection signal.

Set condition

Emergency Notification Signal (ENS) period is not within 10% of 0.001 or 0.1 seconds, and duty cycle is not between 60% and 40%.

Clear condition

ENS period is within 10% of 0.001 or 0.1 seconds and duty cycle is between 60% and 40%.

Signals to check

These diagnostic fields are associated with VCLEFT_a350. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ens Duty VCLEFT_a350_ensDuty %
Ens Period VCLEFT_a350_ensPeriod s
Ens Timed Out VCLEFT_a350_ensTimedOut —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a350.

Browse all VCLEFT alert codes