Skip to content

VCLEFT_a206 — Max Chrge Sssion Tmeout

Full alert identifier: VCLEFT_a206_maxChrgeSssionTmeout

Alert description

The low voltage (LV) battery charge cycle was stopped before it reached either its Amp hour or current targets, as the maximum time period for a charging session timeout had been reached.

Potential impact

Increased energy drain when the vehicle is idle, which may cause lower than expected vehicle state of charge (SOC). LV battery may have lower charge than expected.

Set condition

The vehicle controller detects the maximum LV battery charging session timeout is reached.

Clear condition

The next LV battery charging session starts.

Signals to check

These diagnostic fields are associated with VCLEFT_a206. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
IBS Amp Hours VCLEFT_a206_IBSAmpHours Ah
IBS Current VCLEFT_a206_IBSCurrent A
LV Battery Temp VCLEFT_a206_LVBatteryTemp
127
SNA
degC
Amp Hour Target Not Reached VCLEFT_a206_ampHourTargetNotReached —
Current Not Tapered VCLEFT_a206_currentNotTapered —
First Charge OTA VCLEFT_a206_firstChargeOTA —
First Charge POR VCLEFT_a206_firstChargePOR —
Frunk Open VCLEFT_a206_frunkOpen —
Show 1 more field
Signal Unit
Service Mode VCLEFT_a206_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a206.

Browse all VCLEFT alert codes