VCLEFT_a206 — Max Chrge Sssion Tmeout
Full alert identifier: VCLEFT_a206_maxChrgeSssionTmeout
Alert description
The low voltage (LV) battery charge cycle was stopped before it reached either its Amp hour or current targets, as the maximum time period for a charging session timeout had been reached.
Potential impact
Increased energy drain when the vehicle is idle, which may cause lower than expected vehicle state of charge (SOC). LV battery may have lower charge than expected.
Set condition
The vehicle controller detects the maximum LV battery charging session timeout is reached.
Clear condition
The next LV battery charging session starts.
Signals to check
These diagnostic fields are associated with VCLEFT_a206. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
IBS Amp Hours
VCLEFT_
|
Ah |
IBS Current
VCLEFT_
|
A |
LV Battery Temp
VCLEFT_
|
degC |
Amp Hour Target Not Reached
VCLEFT_
|
— |
Current Not Tapered
VCLEFT_
|
— |
First Charge OTA
VCLEFT_
|
— |
First Charge POR
VCLEFT_
|
— |
Frunk Open
VCLEFT_
|
— |
Show 1 more field
| Signal | Unit |
|---|---|
Service Mode
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a206.