Skip to content

VCLEFT_a171 — 12v Uv

Full alert identifier: VCLEFT_a171_12vUv

Alert description

The battery voltage measurement, nominally 12 volts, was lower than expected.

Potential impact

12V Battery or low voltage systems may be damaged

Set condition

The vbat voltage measurement, is lower than 6.0 volts. If the measurement is lower than 0.25 volts, we do not set this alert, as this would indicated the switch supply is disabled.

Clear condition

Caliper state machine exits csmState CSM_FAULT

Signals to check

These diagnostic fields are associated with VCLEFT_a171. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
12 V Filt VCLEFT_a171_12vFilt V
Nv Filt VCLEFT_a171_nvFilt V
Pv Filt VCLEFT_a171_pvFilt V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a171.

Browse all VCLEFT alert codes