Alert description

The battery voltage measurement, nominally 12 volts, was higher than expected.

Potential impact

12V Battery or low voltage systems may be damaged

Set condition

The vbat voltage measurement is higher than 18.5 volts.

Clear condition

Caliper state machine exits csmState CSM_FAULT

Signals to check

These diagnostic fields are associated with VCLEFT_a170. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
12 V Filt VCLEFT_a170_12vFilt V
Nv Filt VCLEFT_a170_nvFilt V
Pv Filt VCLEFT_a170_pvFilt V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a170.