VCFRONT_a508 — Bridge eFuse Load Shed

Full alert identifier: VCFRONT_a508_bridgeEFuseLoadShed

Alert description

The Bridge EFuse current reached 120A and is at danger of tripping the EFuse if LV loads are not decreased

Potential impact

Convenience features will be disabled to limit LV system current draw

Set condition

The Bridge EFuse is greater than 120A for 100ms

Clear condition

The Bridge EFuse current is less than 120A until PCS EFuse Loadshed Stage is MIN

Signals to check

These diagnostic fields are associated with VCFRONT_a508. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temp VCFRONT_a508_ambientTemp degC
Bridge E Fuse Current VCFRONT_a508_bridgeEFuseCurrent A
Bridge E Fuse Temp VCFRONT_a508_bridgeEFuseTemp degC
Frunk Open VCFRONT_a508_frunkOpen —
Service Mode VCFRONT_a508_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a508.

Browse all VCFRONT alert codes