VCFRONT_a498 — PCS eFuse OVT Load Shed

Full alert identifier: VCFRONT_a498_PCSEFuseOVTLoadShed

Alert description

The PCS EFuse reached 133degC and is at danger of tripping if LV loads are not throttled below 175A

Potential impact

Convenience features will be disabled to limit LV system current draw

Set condition

The PCS EFuse is greater than 133degC for 500ms

Clear condition

The PCS EFuse is less than 133degC until PCS EFuse Loadshed Stage is MIN

Signals to check

These diagnostic fields are associated with VCFRONT_a498. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
PCSE Fuse Current VCFRONT_a498_PCSEFuseCurrent A
Ambient Temp VCFRONT_a498_ambientTemp degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a498.