VCFRONT_a487 — Front OPC eFuse Fault

Full alert identifier: VCFRONT_a487_frontOPCEFuseFault

Alert description

The Front Oil Pump Controller eFuse has tripped.

Potential impact

Powertrain performance may be limited.

Set condition

Too much current detected by the Oil Pump Front high side driver.

Clear condition

Current detected by the Oil Pump Front high side driver is back within a nominal range.

Signals to check

These diagnostic fields are associated with VCFRONT_a487. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Front OPCE Fuse Current VCFRONT_a487_frontOPCEFuseCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a487.