Skip to content

VCFRONT_a477 — Dif eFuse Fault

Full alert identifier: VCFRONT_a477_difEFuseFault

Alert description

The front vehicle controller has opened the voltage supply circuit to the front drive inverter ECU.

Potential impact

Powertrain performance may be limited.

Set condition

A fault is reported by the front drive inverter eFuse circuitry.

Clear condition

A fault is no longer reported by the front drive inverter eFuse circuitry.

Signals to check

These diagnostic fields are associated with VCFRONT_a477. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Dif E Fuse Current VCFRONT_a477_difEFuseCurrent A
Dif E Fuse Temp VCFRONT_a477_difEFuseTemp degC
Dif E Fuse Voltage VCFRONT_a477_difEFuseVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a477.

Browse all VCFRONT alert codes