Skip to content

VCFRONT_a470 — Implausible Pd Pl Detected

Full alert identifier: VCFRONT_a470_implausiblePdPlDetected

Alert description

Difference between the discharge pressure and liquid pressure (Pd-Pl) increased. Discharge lines or Liquid Cooled Condenser (LCC) or Shut Off Valve (SOV) may be blocked.

Potential impact

Thermal performance is degraded.

Set condition

Pd-Pl is greater than 6 bar for 5 consecutive seconds.

Clear condition

Pd-Pl is less than 4 bar for 5 consecutive seconds.

Signals to check

These diagnostic fields are associated with VCFRONT_a470. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pressure Discharge VCFRONT_a470_pressureDischarge bar
Pressure Liquid VCFRONT_a470_pressureLiquid bar

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a470.

Browse all VCFRONT alert codes