Skip to content

VCFRONT_a343 — Vcright Fast Trip Slope

Full alert identifier: VCFRONT_a343_vcrightFastTripSlope

Alert description

The right vehicle controller eFuse reported a current slope > 120A/ms.

Potential impact

The eFuse may have tripped.

Set condition

120A/ms eFuse current slope detected.

Clear condition

Less than 120A/ms eFuse current slope.

Signals to check

These diagnostic fields are associated with VCFRONT_a343. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a343_avgCurrent A
Max Current VCFRONT_a343_maxCurrent A
Max Slope VCFRONT_a343_maxSlope A/ms
Vehicle State VCFRONT_a343_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a343.

Browse all VCFRONT alert codes