Skip to content

VCFRONT_a345 — Epas3p Fast Trip Slope

Full alert identifier: VCFRONT_a345_epas3pFastTripSlope

Alert description

The primary power steering eFuse reported a current slope > 120A/ms.

Potential impact

The eFuse may have tripped.

Set condition

120A/ms eFuse current slope detected.

Clear condition

Less than 120A/ms eFuse current slope.

Signals to check

These diagnostic fields are associated with VCFRONT_a345. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a345_avgCurrent A
Max Current VCFRONT_a345_maxCurrent A
Max Slope VCFRONT_a345_maxSlope A/ms
Vehicle State VCFRONT_a345_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a345.

Browse all VCFRONT alert codes