Skip to content

VCFRONT_a308 — Frunk Sec Under Current

Full alert identifier: VCFRONT_a308_frunkSecUnderCurrent

Alert description

The front vehicle controller (VCFRONT) detects the front trunk (also known as the frunk) secondary latch is experiencing an undercurrent condition.

Potential impact

The frunk secondary latch may be disconnected.

Set condition

The frunk secondary latch draws less current than expected.

Clear condition

The frunk secondary latch stops actuating or draws current within the expected range.

Signals to check

These diagnostic fields are associated with VCFRONT_a308. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Actuator Current VCFRONT_a308_actuatorCurrent A
Temperature VCFRONT_a308_temperature degC
Voltage VCFRONT_a308_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a308.

Browse all VCFRONT alert codes