Skip to content

VCFRONT_a306 — Frunk Pri Under Current

Full alert identifier: VCFRONT_a306_frunkPriUnderCurrent

Alert description

The front vehicle controller (VCFRONT) detects the front trunk (also known as the frunk) primary latch is experiencing an undercurrent condition.

Potential impact

The frunk primary latch may be disconnected.

Set condition

The frunk primary latch draws less current than expected.

Clear condition

The frunk primary latch stops actuating or draws current within the expected range.

Signals to check

These diagnostic fields are associated with VCFRONT_a306. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Actuator Current VCFRONT_a306_actuatorCurrent A
Temperature VCFRONT_a306_temperature degC
Voltage VCFRONT_a306_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a306.

Browse all VCFRONT alert codes