VCFRONT_a288 — Cc Left Exv Fault

Full alert identifier: VCFRONT_a288_ccLeftExvFault

Alert description

The left cabin condenser EXV's motor driver has reported a fault.

Potential impact

Cabin / powertrain cooling and heating performance may be limited.

Set condition

The EXV motor driver has reported a fault.

Clear condition

The EXV motor driver no longer reports a fault.

Signals to check

These diagnostic fields are associated with VCFRONT_a288. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCFRONT_a288_chargePumpUndervoltage —
Driver Has Comm Error VCFRONT_a288_driverHasCommError —
Driver State VCFRONT_a288_driverState —
Driver Therm Shutdown VCFRONT_a288_driverThermShutdown —
Driver Therm Warn VCFRONT_a288_driverThermWarn —
Is Coil Open X VCFRONT_a288_isCoilOpenX —
Is Coil Open Y VCFRONT_a288_isCoilOpenY —
Is Coil Short XN Gnd VCFRONT_a288_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCFRONT_a288_isCoilShortXNVbb —
Is Coil Short XP Gnd VCFRONT_a288_isCoilShortXPGnd —
Is Coil Short XP Vbb VCFRONT_a288_isCoilShortXPVbb —
Is Coil Short YN Gnd VCFRONT_a288_isCoilShortYNGnd —
Is Coil Short YN Vbb VCFRONT_a288_isCoilShortYNVbb —
Is Coil Short YP Gnd VCFRONT_a288_isCoilShortYPGnd —
Is Coil Short YP Vbb VCFRONT_a288_isCoilShortYPVbb —
Undervoltage VCFRONT_a288_undervoltage —