Skip to content

VCDOORRR_a175 — Window Seal Defect

Full alert identifier: VCDOORRR_a175_windowSealDefect

Alert description

The pinch algorithm detected a seal defect during the second rollup of calibration. Window seals / glass / door fitment may need adjustment to allow smoother window rolling.

Potential impact

Windows that trigger this alert are likely to false pinch during future window roll-ups.

Set condition

A seal defect was detected during the second roll up of calibration

Clear condition

Run window calibration after fixing defect

Signals to check

These diagnostic fields are associated with VCDOORRR_a175. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Abs Accel Tripped VCDOORRR_a175_absAccelTripped —
Lookback Index VCDOORRR_a175_lookbackIndex —
Position At Pinch VCDOORRR_a175_positionAtPinch mm
Rel Accel Tripped VCDOORRR_a175_relAccelTripped —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORRR_a175.

Browse all VCDOORRR alert codes