Skip to content

VCDOORRR_a150 — Window Pinch

Full alert identifier: VCDOORRR_a150_windowPinch

Alert description

Window pinch event detected

Potential impact

Window will not complete actuation and reverse

Set condition

Window pinch condition detected, see alert payload for pinch reason

Clear condition

Immediate

Signals to check

These diagnostic fields are associated with VCDOORRR_a150. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Abs Accel Exceedance VCDOORRR_a150_absAccelExceedance %
Lookback Index VCDOORRR_a150_lookbackIndex —
Movement Time Ms VCDOORRR_a150_movementTimeMs ms
Rel Accel Exceedance VCDOORRR_a150_relAccelExceedance %
Speed Exp Score VCDOORRR_a150_speedExpScore —
Treated In Gear VCDOORRR_a150_treatedInGear —
Window Pinch Reason VCDOORRR_a150_windowPinchReason
0
NONE
1
POWER
2
POWER DIV SPEED
3
POWER CRUDE
4
ACCEL LOOKBACK
5
UNUSED
—
Window Position VCDOORRR_a150_windowPosition mm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORRR_a150.

Browse all VCDOORRR alert codes