VCDOORRL_a121 — eFuse Management Continuous16 V
Full alert identifier: VCDOORRL_a121_eFuseManagementContinuous16V
Alert description
Unexpected voltage seen on continuous device outputs
Potential impact
Electrical loads for door switch LED, door pocket LED, door puddle LED, and power 15v0 sw fused rail may be unavailable.
Set condition
Voltage is above 10V for 200ms on at least one of the device outputs while none of them are being driven
Clear condition
Voltage is below 10V and 10 seconds have passed since alert was set. If the alert sets 3 or more times, controller reset is required.
Signals to check
These diagnostic fields are associated with VCDOORRL_a121. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Continuous 16 VE Fuse Monitor
VCDOORRL_
|
V |
E Fuse Trip Count
VCDOORRL_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORRL_a121.