Skip to content

SSFA_a160 — TLE5501 Fault

Full alert identifier: SSFA_a160_TLE5501Fault

Alert description

The primary motor position sensor has been deemed invalid.

Potential impact

The motor is disqualified and rack control health is degraded.

Set condition

The motor position sensor signals have failed a safety check.

Clear condition

The alert will clear if the motor position sensor signals satisfy safety requirements for a sufficient window. The steering rack should be replaced.

Signals to check

These diagnostic fields are associated with SSFA_a160. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Angle Diff ND SSFA_a160_angleDiff_ND —
Angle Diff PD SSFA_a160_angleDiff_PD —
Angle Diff PN SSFA_a160_angleDiff_PN —
Angle Valid D SSFA_a160_angleValid_D —
Angle Valid N SSFA_a160_angleValid_N —
Angle Valid P SSFA_a160_angleValid_P —
Calibration Diff SSFA_a160_calibrationDiff —
Calibration N SSFA_a160_calibrationN —
Show 7 more fields
Signal Unit
Calibration P SSFA_a160_calibrationP —
Common Mode Cos SSFA_a160_commonModeCos —
Common Mode Sin SSFA_a160_commonModeSin —
Length D SSFA_a160_lengthD —
Length N SSFA_a160_lengthN —
Length P SSFA_a160_lengthP —
Old Calibration Present SSFA_a160_oldCalibrationPresent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFA_a160.

Browse all SSFA alert codes