SSFA_a149 — MAQ473 GQE Fault
Full alert identifier: SSFA_a149_MAQ473GQEFault
Alert description
The primary motor position sensor has been deemed invalid.
Potential impact
The motor is disqualified and handwheel feedback health is degraded.
Set condition
The motor position sensor experiences an issue affecting configuration and/or communication, or magnetic flags are set.
Clear condition
The sensor configuration is successful, the angle reading is active and valid, and there are no magnetic flags set.
Signals to check
These diagnostic fields are associated with SSFA_a149. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Config Fault
SSFA_
|
— |
Config State
SSFA_
|
— |
Mag H
SSFA_
|
— |
Mag L
SSFA_
|
— |
Mag LH Fault
SSFA_
|
— |
Request Data
SSFA_
|
— |
Response Data
SSFA_
|
— |
Response Invalid
SSFA_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFA_a149.